Our Products
Instrumentation Cables

Instrumentation Cables

A) PVC/PVC Overall Screened Instrument Cable BS 5308 Part 2 : Type 1 300/500v

Polyvinyl Chloride Insulated Polyvinyl Chloride Sheathed Overall Screened Instrument Cable

Description:

Single pair and multi-pair cables with copper conductor, PVC insulated, overall screened and PVC sheathed. Voltage rated at 300/500V.

Construction

  • Conductor:
    Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
  • Insulation:
    PVC (Polyvinyl Chloride) / PE
  • Pairing:
    Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.
    Note: Two pair cables with overall screen shall have four cores laid in quad formation.
  • Pair identification:
    Colour code as per Appendix B or as per customer specification
  • Cabling:
    Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation.
  • Overall Screening:
    Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
  • Sheath:
    PVC (Polyvinyl Chloride).

B) PVC/PVC Overall Screened Instrument Cable BS 5308 Part 2 : Type 1 300/500v

Polyvinyl Chloride Insulated Polyvinyl Chloride Sheathed Individual & Overall Screened Instrument Cable

Description

Multi-pair cables with copper conductor, PVC insulated, individual & overall screened and PVC sheathed. Voltage rated at 300/500V.

Construction

  • Conductor:
    Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
  • Insulation:
    PVC (Polyvinyl Chloride) / PE
  • Pairing:
    Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.
    Note: Two pair cables with overall screen shall have four cores laid in quad formation.
  • Pair identification:
    Colour code as per Appendix B or as per customer specification
  • Individual Screening:
    Each pair screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
  • Cabling:
    Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation
  • Overall Screening:
    Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
  • Sheath:
    PVC (Polyvinyl Chloride).

C) PVC/PVC/SWA/PVC Overall Screened Instrument Cable BS 5308 Part 2 : Type 2 300/500v

Polyvinyl Chloride Insulated Polyvinyl Chloride Bedding Steel Wire Armoured Polyvinyl Chloride Sheathed Overall Screened Instrument Cable

Description:

Single pair and multi-pair cables with copper conductor, PVC insulated, overall screened, PVC bedding, Steel wire armoured and PVC sheathed. Voltage rated at 300/500V

Construction

  • Conductor:
    Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
  • Insulation:
    PVC (Polyvinyl Chloride) / PE
  • Pairing:
    Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.
    Note: Two pair cables with overall screen shall have four cores laid in quad formation.
  • Pair identification
    Colour code as per Appendix B or as per customer specification
  • Cabling
    Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation
  • Overall Screening
    Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
  • Bedding
    PVC (Polyvinyl Chloride).
  • Armouring
    Galvanized steel round wire over the bedding.
  • Sheath
    PVC (Polyvinyl Chloride).

D) PVC/PVC/SWA/PVC Individual & Overall Screened Instrument Cable BS 5308 Part 2 : Type 2 300/500v

Polyvinyl Chloride Insulated Polyvinyl Chloride Bedding Steel Wire Armoured Polyvinyl Chloride Sheathed Individual & Overall Screened Instrument Cable

Description

Multi-pair cables with copper conductor, PVC insulated, individual & overall screened, PVC bedding, Steel wire armoured and PVC sheathed. Voltage rated at 300/500V

Construction

  • Conductor
    Plain annealed/tinned circular stranded copper conductor, conform to BS 6360 / IS:8130
  • Insulation
    PVC (Polyvinyl Chloride) / PE
  • Pairing
    Two insulated cores shall be uniformly twisted together to form a pair with maximum lay length of 100 mm.
  • Pair identification
    Colour code as per Appendix B or as per customer specification
  • Individual Screening
    Each pair screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
  • Cabling
    Twisted pairs are laid up together, if necessary filled with nonhygroscopic material compatible with the insulation
  • Overall Screening
    Accumulated pairs screened with aluminium/mylar tape, helically applied with the metallic side down, in electrical contact with a tinned annealed copper drain wire of 0.5 mm2.
  • Bedding
    PVC (Polyvinyl Chloride).
  • Armouring
    Galvanized steel round wire over the bedding.
  • Sheath
    PVC (Polyvinyl Chloride).

View Appendix B View Constructional Specifications View Electrical Characteristics